VEGA

Conveyor belt control

Conveyor belt control

Conveyor transfer points

In most cases, coarse and fine bulk solids are transported on conveyor belts within a production facility. To achieve an even throughput and compensate for quantity fluc-tuations during transport, conveyor transfer points are integrated in the conveyance system. Incoming bulk solids are stored briefly in buffer silos at these points to avoid overfilling. The level, or at least the limit level, has to be monitored here.

Level monitoring with VEGAPULS 67

VEGAPULS 67 measures the level in the buffer silos of the conveyor transfer points and thus regulates the conveyor as well as the production processes. Since the instrument is completely unaffected by the extreme dust generation and other ambient conditions, reliable measurement is guaranteed.

Overfill protection with VEGACAP 65

VEGACAP 65 is extremely robust and thus ideal for use with heavy bulk solids. The shortenable cable electrode allows flexible adaptation of the switching point. Its gravity weight of steel or stainless steel resists even the hardest blows and ensures a long service life.

Overfill protection with VEGAMIP 61

The non-contact level switch VEGAMIP 61 demonstrates its prowess in extremely rough applications. It safeguards against overfilling without direct contact to the medium and is thus absolutely wear-free.

» VEGAPULS 67

Measuring range
up to 15 m
Process fitting
mounting strap
compression flanges from DN 80, 3"
Process temperature
-40 … +80 °C
Process pressure
-1 … +2 bar
(-100 … +200 kPa)
Measurement accuracy
+/- 2 mm
SIL qualification
up to SIL2

» VEGACAP 65

Version
partly insulated cable
Measuring range
up to 32 m
Process fitting
thread from G1, 1 NPT
flanges from DN 50, 2"
Materials
316L, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)

» VEGAMIP R61

Measuring range
up to 100 m
Process fitting
thread G1½, 1½ NPT
flanges
Clamp
Process temperature
-40 … +80 °C
+450 °C with mounting adapter
Process pressure
-1 … +4 bar (-100 … +400 kPa)

» VEGAMIP T61

Measuring range
up to 100 m
Process fitting
thread G1½, 1½ NPT
flanges
Clamp
Process temperature
-40 … +80 °C
+450 °C with mounting adapter
Process pressure
-1 … +4 bar
(-100 … +400 kPa)